Categories
Browse records
New Products
  • USP Standard Gel Clot Kit
  • Gel Clot method Multiple Test vial
    Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial

    Gel Clot Method Lyophilized Amebocyte Lysate Multi-test Vial G17 is especially suitable for endotoxin detection in large amounts. Bioendo's Lysate reagent features strong resistance to interference and strong improvement for heat stability.

  • Endotoxin Assay
    Endotoxin Assay Kit for Water and Dialysate (Gel Clot Assay)

    Endotoxin Assay Kit for Water and Dialysate (Gel Clot Assay) assays the endotoxin in water or dialysate by using gel clot technique. Relating operation conforms to USP & EP. Endotoxin-specific Amebocyte Lysate is included by this kit, which will well avoid false positive reaction with Fungi (1,3)-β-D-glucan.

  • GC Endotoxin Test Kit
    Bioendo GC Endotoxin Test Kit (Gel Clot Assay)

    Bioendo GC Endotoxin Test Kit (Gel Clot Assay) includes Amebocyte Lysate, CSE and Water for BET. This will well avoid the mismatching between Amebocyte Lysate and CSE. The Kit is especially suitable for you when you need to do lots of endotoxin detection. Customized gel-clot endotoxin assay kit is also available upon your demand.

  • TAL Endotoxin Testing Assay
    End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling)

    Bioendo EC Endotoxin Test Kit provides a fast measurement for endotoxin quantification. The endotoxin in the sample activates a cascade of enzymes in Amebocyte Lysate, the activated enzyme splits the synthetic substrate, releasing a yellow-colored product with maximum absorbance at 405nm. For End-point Chromogenic Endotoxin Test Kit without Diazo Coupling, a regular spectrophotometer or plate reader is required to read the absorbance at 405nm.

  • Kinetic Turbidimetric Assay
    Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay)

    Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. It could be applied to test the endotoxin level of injectable drugs and implantable medical devices.

Control Standard Endotoxin (CSE)

Control Standard Endotoxin (CSE) is an economic alternative to Reference Standard Endotoxin (RSE) in constructing standard curves, validating product and preparing controls in endotoxin test.

  • Product Origin:

    China
  • Shipping Port:

    Xiamen/Guangzhou/Shenzhen
  • Lead Time:

    Match Lysate reagent
  • Introduction
  • Order information
  • Product qualification
  • FAQ
  • Accessary products

1. Product Information

Control Standard Endotoxin (CSE) is extracted from E.coli O111:B4. CSE is an economic alternative to Reference Standard Endotoxin (RSE) in constructing standard curves, validating product and preparing controls in Lyophilized Amebocyte Lysate test. The labeled potency of CSE endotoxin E.coli standard is referenced against RSE. The Control Standard Endotoxin could be used with gel clot assay, kinetic turbidimetric assay or kinetic chromogenic assay as the endotoxin testing standards. The Certificate of Analysis will show the matched Lyophilized Amebocyte Lysate reagent lots.


2. Product Parameter

1 - 99 EU/Vial;
1 - 199 EU/Vial; 
200 - 999 EU/Vial


3. Product Feature and Application

Bioendo CSE was labeled by the potency and matched to Lyophilized Amebocyte Lysate reagent lots. Users do not need to do the CSE/RSE ratio assay. Low potency control standard endotoxin is available to avoid lots of steps of dilution to provide convenience for end users. 

Control Standard Endotoxin:

Catalog Number
Potency  (EU/vial)
Package
CSE10V
100 to 999 EU
seal in glass vial, 10vials/pack
CSE100V
1 to 199 EU
seal in glass vial, 10vials/pack
CSE10A
1 to 99 EU
seal in glass ampoule, 10vials/pack

Product Condition:

Control Standard Endotoxin (CSE), extracted from E.coli O111:B4, is an economic alternative to Reference Standard Endotoxin (RSE) in constructing standard curves, validating product and preparing controls in endotoxin test. The potency of CSE is referenced against USP Reference Standard Endotoxin, and labeled in the Certificate of Analysis.


Note match issue:  CSE have to match Lysate reagent.

Pyrogen free tips

Endotoxin free tubes

Send detail to GET quote now

Esteem Your specified requirements will help us make a complete solution and offer feedback to you quickly. Especially Purchase company Name/Tel/Whatsapp or Wechat for efficient communication.

CONTACT US

Add: 131 Xinjia Road,Haicang Xinyang Industrial zone,Xiamen,China

Contact Person: Haiping Wu
Tel: 86-592-6885886
Fax: 86-592-2095294
Mobile: +8618059871066

Email: sales@houshiji.com 

haipingwu@houshiji.com

Xiamen Bioendo Technology Co., Ltd.

Copyright © Xiamen Bioendo Technology Co., Ltd. All Rights Reserved

 

Chat now

Live Chat

Esteem Your specified requirements will help us make a complete solution and offer feedback to you quickly. Especially Purchase company Name/Tel/Whatsapp or Wechat for efficient communication.

home

products

company

contact