Bioendo GC Endotoxin Test Kit (Gel Clot Assay) includes Amebocyte Lysate, CSE and Water for BET. This will well avoid the mismatching between Amebocyte Lysate and CSE. The Kit is especially suitable for you when you need to do lots of endotoxin detection. A variety of gel-clot endotoxin assay kits are also available upon your demand.
| Catalog No. | Description & Kit Contents | Sensitivity Range |
| GC08170030 | 50 Tests/Vial,128 Tests/Kit 8 Gel Clot Lyophilized Amebocyte Lysate, 1.7ml (16 Tests/Vial); 4 CSE10V; 2 Water for BET, 50ml/vial; | 0.03 EU/mL |
| GC08170060 | 0.06 EU/mL | |
| GC08170125 | 0.125 EU/mL | |
| GC08170250 | 0.25 EU/mL | |
| GC08170500 | 0.5 EU/mL |
| Catalog No. | Description & Kit Contents | Sensitivity Range |
| GC90520030 | 50 Tests/Vial,4500 Tests/Kit 90 Gel Clot Lyophilized Amebocyte Lysate, 5.2ml (50 Tests/Vial); 20 CSE10V; | 0.03 EU/mL |
| GC90520060 | 0.06 EU/mL | |
| GC90520125 | 0.125 EU/mL | |
| GC90520250 | 0.25 EU/mL | |
| GC90520500 | 0.5 EU/mL |
| Catalog No. | Description & Kit Contents | Sensitivity Range |
| GC08520030 | 50 Tests/Vial,400 Tests/Kit 8 Gel Clot Lyophilized Amebocyte Lysate, 5.2ml (50 Tests/Vial); 4 CSE10V; 2 Water for BET, 50ml/vial | 0.03 EU/mL |
| GC08520060 | 0.06 EU/mL | |
| GC08520125 | 0.125 EU/mL | |
| GC08520250 | 0.25 EU/mL | |
| GC08520500 | 0.5 EU/mL |
The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis, MSDS.
Note: For other sizes/specifications not listed above, please contact our customer service team.
Email: Eve@bioendo.com
Tel: +86 18065928551
FLEXIBLE CONFIGURATIONS
Multiple Test Configurations
Flexible configurations meet different laboratory testing requirements.
WIDE SENSITIVITY RANGE
Wide Range of Sensitivities
Suitable for various bacterial endotoxin detection applications.
COMPLETE SOLUTION
No Additional Reagents Required
No additional preparation of basic reagents is required.
SIMPLE GEL CLOT ASSAY
User-Friendly, Instrument-Free
A user-friendly, instrument-free solution compatible with dry heat incubators or water baths, enabling easy operation and visual result reading for routine endotoxin testing.
RELIABLE QC PERFORMANCE
USP-Standardized & COA Supplied
USP-standardized for sensitivity and CSE potency, supplied with COA, and designed for regulated pharmaceutical QC labs.
RELATED EQUIPMENT
Compatible Endotoxin Detection Systems
Compatible instruments support different endotoxin detection workflows, from routine laboratory testing to fully automated analysis.
PRODUCT
DESCRIPTION
Full Wavelength Absorption Light Bacterial Endotoxin Detector
Fluorescent Endotoxin Detection Instrument
Multifunctional Endotoxin Detector
Bacterial Endotoxin Detector
Intelligent Fully-Automatic Endotoxin Detection System
Phoenix Q9
Intelligent Fully-Automatic Endotoxin Detection System
Modular Intelligent Fully-Automatic Endotoxin Detection System
Click the product name to view product details.
FREQUENTLY ASKED QUESTIONS
Kinetic Turbidimetric Method
Q1
Are there any instrument requirements for the kinetic turbidimetric method?
The kinetic turbidimetric method requires a detection instrument with temperature control and the ability to dynamically measure absorbance values. We recommend the Limulus Amebocyte Lysate Microbial Rapid Detection System ELX808IULALXH, which features wavelengths of 340, 405, 490, 540, and 630 nm, and maintains a temperature accuracy of 37±0.1°C. This instrument strongly supports accurate kinetic turbidimetric experiments and helps reduce experimental errors.
Q2
How should samples be tested?
Initial sample testing requires a preliminary experiment. Prepare multiple dilution gradients of the sample to perform a recovery test and determine the appropriate dilution factor. For detailed guidance, refer to the instruction manual and the Chinese Pharmacopoeia.
Q3
What causes a poorly constructed standard curve?
(1)Carefully read the instruction manual and certificate of analysis to ensure the wavelength and Onset OD are correctly set. Turn on the instrument in advance, set up the program, and preheat it to 37°C.
(2)Has the endotoxin been thoroughly shaken? Simply shaking by hand a few times or using a shaker is insufficient. Endotoxin must be thoroughly mixed using a vortex mixer.
(3)Has the LAL reagent been vortexed vigorously? The LAL reagent must be used within 10 minutes. Therefore, first prepare the endotoxin working standard and samples, then reconstitute the LAL reagent. After reconstitution, gently mix the reagent and let it stand until the bubbles dissipate before use. Always reconstitute the LAL reagent and endotoxin according to the instruction manual.