The Bioendo® rCR Endotoxin Test Kit employs genetic recombination technology to express the key zymogens of the horseshoe crab coagulation cascade (Factor C, Factor B, and proclotting enzyme) in eukaryotic cells. Endotoxin sequentially activates Factor C, Factor B, and proclotting enzyme. The activated proclotting enzyme then cleaves the chromogenic substrate, releasing yellow p-nitroaniline (pNA), which is quantified at 405 nm. The entire process is free of animal-derived materials, ensuring accuracy, reliability, and environmental sustainability.
Catalog No.Description & Kit ContentsSensitivity Range
RCR0428S
104 Tests/Kit
4 Recombinant Cascade Reagents -- 2.8ml/vial, 26 Test/vial;
4 Reconstitution Buffer -- 3.0ml/vial, 26 Test/vial;
2 Control Standard Endotoxin -- 40EU(CoA);
2 Water for BET -- 50ml/vial, 104 Test/kit
0.001-10 EU/mL
RCR04280.005-5 EU/mL
The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis, MSDS.
Note:For other sizes/specifications not listed above, please contact our customer service team.
Email: Eve@bioendo.com
Tel:      +86 18065928551


INSTRUMENT COMPATIBILITY
Seamless Integration
Use with existing chromogenic LAL assay instruments without modifying your current testing workflow.
HIGH SENSITIVITY
0.001 EU/mL
Reliable endotoxin detection down to 0.001 EU/mL.
       
CONSISTENT PERFORMANCE
Batch-to-Batch Reproducibility
Excellent batch-to-batch reproducibility ensures dependable test results.
ENDOTOXIN-SPECIFIC
Factor G Pathway Insensitive
Insensitive to (1→3)-β-D-glucan, minimizing false positives associated with the Factor G pathway.
       
   
RELATED EQUIPMENT
Compatible Endotoxin Detection Systems
Compatible instruments support different endotoxin detection workflows, from routine laboratory testing to fully automated analysis.
PRODUCT
DESCRIPTION
Full Wavelength Absorption Light Bacterial Endotoxin Detector
Fluorescent Endotoxin Detection Instrument
Multifunctional Endotoxin Detector
Bacterial Endotoxin Detector
Intelligent Fully-Automatic Endotoxin Detection System
Phoenix Q9
Intelligent Fully-Automatic Endotoxin Detection System
Modular Intelligent Fully-Automatic Endotoxin Detection System
Click the product name to view product details.