Gel Clot TAL/LAL Single Test in Vial is developed based on USP. Directly encapsulating in glass reaction tube in vacuum environment, the product has extremely low moisture content and excellent quality. The vial packed the product could be directly used to incubate in water bath or dry heat incubator.
Catalog No.Description & Kit ContentsSensitivity Range
G020030Single Test/Vial, 50 Vials/Box0.03 EU/mL
G020060Single Test/Vial, 50 Vials/Box0.06 EU/mL
G020125Single Test/Vial, 50 Vials/Box0.125 EU/mL
G020250Single Test/Vial, 50 Vials/Box0.25 EU/mL
G020500Single Test/Vial, 50 Vials/Box0.5 EU/mL
The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis, MSDS.
Note:  For other sizes/specifications not listed above, please contact our customer service team.
Email:  Eve@bioendo.com
Tel:  +86 18065928551
       
WHY CHOOSE OUR LAL REAGENT
Single Test LAL Reagent
       
SINGLE VIAL DESIGN
Reduced Reagent Waste
Single vial design helps reduce reagent waste and provides a convenient format for individual testing.
READY-TO-USE
No Reagent Preparation
No reagent preparation is required, simplifying operation and reducing preparation time.
FLEXIBLE WORKFLOW
Convenient Endotoxin Testing
Flexible testing workflow adapts easily to different laboratory testing requirements.
SMALL BATCH TESTING
Ideal for Small Test Batches
Suitable for small batch testing, helping laboratories use reagents efficiently according to testing needs.
EASY-TO-OPEN VIAL
Convenient Vial Packaging
Packed in easy-to-open vials for convenient handling and straightforward laboratory operation.
DIRECT SAMPLE ADDITION
Add Samples Directly
Samples can be added directly to the vial, simplifying the testing process and reducing handling steps.


RELATED EQUIPMENT
Compatible Endotoxin Detection Systems
Compatible instruments support different endotoxin detection workflows, from routine laboratory testing to fully automated analysis.
                   PRODUCT
DESCRIPTION
Full Wavelength Absorption Light Bacterial Endotoxin Detector
Intelligent Fully-Automatic Endotoxin Detection System
                   Phoenix Q9
Intelligent Fully-Automatic Endotoxin Detection System
Modular Intelligent Fully-Automatic Endotoxin Detection System
Click the product name to view product details.
PRECAUTIONS
Important Testing Precautions
 01This kit is intended for qualitative in vitro detection of bacterial endotoxins. Under no circumstances should the reagents be introduced into the body by any route.
 02Please use the endotoxin working standard that corresponds to this batch of LAL reagent.
 03All utensils that come into contact with reagents and test samples must be endotoxin-free. Microbial contamination must be prevented during the testing process.
 04The term "depyrogenated" in this manual refers to an endotoxin concentration of less than 0.005 EU/ml.
 05The pH of the mixture of the test sample and LAL reagent should be between 6 and 8. If it falls outside this range, adjust it using depyrogenated buffer, 0.1 M sodium hydroxide, or 0.1 M hydrochloric acid.
 06If the test sample may contain substances that interfere with the LAL test, an interference test must be performed; please refer to Interference Test for the Test Sample            .